Oxmoor MCS Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audio Oxmoor MCS herunter. Oxmoor MCS User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - ROOM COMBINING SYSTEM

Installation&OperationManualMCSROOM COMBINING SYSTEM

Seite 2 - TABLE OF CONTENTS

FUSEPOWEROXMOORMADE IN USA BY OXMOOR CORPORATIONBIRMINGHAM, ALABAMA ®CHASSISMCS-CCPA-422 INPA-422 OUT1248163264128PA-422 ADDRESSONFigure 1.6: MCS-CC C

Seite 3

Page 9LOCALMUSICVOLUME ONLYOFFONMCS–RP MCS-RP ROOM PANEL(Callouts refer to Figure 1.8)A typical MCS system includes a (standard 3-gang) wall-mounted M

Seite 4 - • Custom screened for your

Page 10SOURCEHEAD-TABLECOMBINEBERKSHIRE ROOMWYNFREY BALLROOMSOURCEHEAD-TABLESOURCEHEAD-TABLERIVERCHASE BALLROOMOFFONCOMBINECOMBINE3. Select desired SO

Seite 5 - MCS SYSTEM DESCRIPTIONS

Page 11LOCALMUSICOFFONROOMS12345678MCS–MVP Master Volume Panel532 4Figure 1.10: MCS-MVP Master Volume PanelMCS-MVP MASTER VOLUME PANEL(Callouts refer

Seite 6 - MCS SYSTEM BLOCK DIAGRAMS

MCS-IB INTERFACE BOX(Callouts refer to Figure 1.11)The MCS-IB serves as an interface for:a. Contact closures (LINK, SOURCE and HEAD-TABLE) to PA-422 s

Seite 7 - MCS-MAINFRAME

MCS-LI LINE INPUT CARD CONNECTIONS(Refer to Figure 2.0)The MCS-LI Line Input Card provides connections foraudio IN and OUT, Room Panel (Remote Volume,

Seite 8 - MCS-LI LINE INPUT CARD

CONNECTIONS TO A CUSTOM ROOM PANEL(Refer to Figure 2.3)Figure 2.3 provides the wiring information required tocustom-fabricate a room panel using Oxmoo

Seite 9 - MCS-LC LOGIC CARD

Figure 2.4: MCS-LC Logic Card ConnectionsMCS-LCMUSIC IN -PAGE MUSIC IN +COMSHIELDCOMCOMBINE LEVELLOCALHEAD 1HEAD 2HEAD 3HEAD 4HEAD 5HEAD 6HEAD 7HEAD 8

Seite 10 - MCS-CC CONTROL CARD

Page 16MCS-MCP MASTER CONTROL PANELCONNECTIONS(Refer to Figure 2.5)The MCS-MCP Master Control Panel and the MCS-IBcommunicate with each other by two 4

Seite 11 - MCS-RP ROOM PANEL

Page 17MCS-IB INTERFACE BOX CONNECTIONS(Refer to Figure 2.6)The MCS-IB Interface Box and the MCS-Mainframecommunicate with each other by a PA-422 seri

Seite 12 - MCS-MCP MASTER CONTROL PANEL

MCS ROOM COMBINING SYSTEM INTRODUCTION ... 1MCS ROOM COMBINING SYSTEM COMPONENTS

Seite 13 - MCS-MVP MASTER VOLUME PANEL

Page 181T2T 3T4T 5T6T7T8T1T2T3T4T5T6T 7T8T 1T2T 3T4T 5T6T7T8TTT9T10 11LOCKCOMCOMCOMCOMV+HEAD TABLESOURCELINKSMCS-MVP INTERFACEPA-422 OUTPUTMCS-MCP INT

Seite 14 - MCS-IB INTERFACE BOX

Page 19MCS-MVP MASTER VOLUME PANELCONNECTIONS(Refer to Figure 2.8)The MCS-MVP Master Volume Panelcommunicates with the system through the MCS-MCP Mast

Seite 15

Page 20PROGRAMMING THE COMBINE BUTTONS(Refer to Figure 3.0)Programming instructs the MCS system as to whichchannels are to be combined when a COMBINE

Seite 16 - (Refer to Figure 2.3)

MCS-MCP MASTER CONTROL PANEL OPERATION(Refer Figure 4.0)NOTE: Each MCS-MCP is custom configured for the system it isto control. Not all functions des

Seite 17 - MCS-LC LOGIC CARD CONNECTIONS

Page 22LOCALMUSICOFFONROOMS12345678MCS–MVP Master Volume PanelResultAll MVP functions operable; no security provided againstunwanted tampering.As long

Seite 18 - CONNECTIONS

Page 23LOCALMUSICVOLUME ONLYOFFONMCS–RP MCS-RP ROOM PANEL(Refer to Figure 4.2)The Room Panel provides a “master” volume control for theroom. The panel

Seite 19

Page 24RC-16MUSICLOCALMUTERC-16MUSICLOCALMUTE1THROUGH11CH 1THROUGHCH 8HEAD TABLELOGIC OUT12345678COMBINE LEVEL+/- 15 dB Trim+/- 15 dB TrimMUSICAUDIO M

Seite 20 - (Refer to Figure 2.7)

Page 25MCS-LI LINE INPUT SPECIFICATIONSAUDIO INAUDIO INAUDIO INAUDIO INAUDIO IN Type ... Electronically

Seite 21 - (Refer to Figure 2.8)

Page 26*SMPTE Method; 60 Hz + 7 kHz mixed 4:1.** Input terminated w/600 ohms, unity gain, adjacent channel driven to +4 dBm output.Specifications subj

Seite 22 - MCS PROGRAMMING

Page 27MCS-PS POWER SUPPLY SPECIFICATIONSMAINS POWERMAINS POWERMAINS POWERMAINS POWERMAINS POWER Internal Supply ...

Seite 23 - (Refer Figure 4.0)

MCS ROOM COMBINING SYSTEM INTRODUCTIONThe MCSTM Room Combining System combines up toeight rooms in any combination. A non-volatilememory feature prese

Seite 24 - (Refer to Figure 4.1)

Page 28Specifications subject to change without notice.LOGIC (LINKS, SOURCE ANDLOGIC (LINKS, SOURCE ANDLOGIC (LINKS, SOURCE ANDLOGIC (LINKS, SOURCE AN

Seite 25 - MCS-RP ROOM PANEL OPERATION

Oxmoor MCS Room Combining SystemFor service information contact:OXMOOR FACTORY SERVICEAdditional Installation & Operation Manuals are available fr

Seite 26 - MCS BLOCK DIAGRAM

TYPICALMASTER CONTROL PANEL• Custom screened for your specific room configuration• Combine, source and head-table switches for each zone• Field-

Seite 27

Page 3MCS SYSTEM DESCRIPTION(Callouts refer to Figures 1.0 and 1.1)• MCS-Mainframe:A 19" rack-mount by 3 rack-unit (5.25") chassis thath

Seite 28

Page 4MCS SYSTEM BLOCK DIAGRAMSLOCALMUSICVOLUME ONLYOFFONMCS–RP 45678LOCALMUSICROOMS12345678MCS – MVP Master Volume PanelMCS ROOM COMBINING SYSTEMMCS

Seite 29 - MCS MECHANICAL SPECIFICATIONS

Page 5Figure 1.3: MCS-MAINFRAME Rear ViewFigure 1.2: MCS-MAINFRAME Front ViewMCS - MAINFRAME DESCRIPTION(Callouts refer to Figures 1.2 and 1.3)1. PO

Seite 30

Page 6MCS-LI LINE INPUT CARD(Callouts refer to Figure 1.4)One MCS-LI Line Input card is required foreach room to be combined. A total of eight LineIn

Seite 31 - OXMOOR FACTORY SERVICE

Page 7MCS-LC LOGIC CARD(Callouts refer to Figure 1.5)One MCS-LC Logic Card is required for each MCSMainframe used.1. LOCAL - Used to set the COMBINE

Kommentare zu diesen Handbüchern

Keine Kommentare